Methodology & transparency
Methodology & sources
Evidence, statutory references and editable assumptions are listed separately below. The current screening reports the published record for Rudolf-Wissell-Haus; calculated results are indicative and depend on the stated inputs and assumptions.
Version 1.0.0 · References last checked 2026-09-26
What this is
A transparent screening of German building energy records, with documented units, sources, gaps and editable assumptions for future analysis. The district record identifies natural gas; its calorific basis is not published and is assumed to be Hs.
What this is not
Not an Energieausweis and not an assessment under DIN EN 16247 or EDL-G. A consumption-based class is only an indicative estimate when the required residential area basis is available; only authorised issuers can issue an Energieausweis. No reported finding establishes future outcomes, statutory compliance, funding eligibility or professional advice.
Emission factors
Direct CO₂ from combustion and electricity generation only; upstream emissions, CH₄ and N₂O are outside this screening. Supplier-specific carriers remain data gaps until documented.
Natural gas emission factors
Direct combustion CO₂ only. German gas invoices usually state kWh on an Hs basis; default input is Hs (invoice). Confirm the invoice basis.
| Parameter | Value / status |
|---|---|
| Hi | 0.2016 |
| Hs | 0.182 |
| Default Input Basis | Hs (invoice) |
- Unit / basis
- kg CO₂/kWh (Hi or Hs)
- Effective / applicable period
- 2023–2030
- Source
- EBeV 2030, Anlage 2 ↗https://www.gesetze-im-internet.de/ebev_2030/anlage_2.html
- Last checked
- 2026-09-26
Gas Hs-to-Hi conversion
kWh Hi = kWh Hs / 1.108; verify carrier-specific calorific value when available.
| Parameter | Value / status |
|---|---|
| Value | 1.108 |
- Unit / basis
- kWh Hs per kWh Hi
- Effective / applicable period
- 2030
- Source
- EBeV 2030, Anlage 2 ↗https://www.gesetze-im-internet.de/ebev_2030/anlage_2.html
- Last checked
- 2026-09-26
Heating oil emission factors
Heizöl EL; direct combustion CO₂ only. Select the unit matching the input.
| Parameter | Value / status |
|---|---|
| Per Hi (kWh) | 0.2664 |
| Per Litre | 2.6763 |
- Unit / basis
- kg CO₂/kWh Hi; kg CO₂/litre
- Effective / applicable period
- 2030
- Source
- EBeV 2030, Anlage 2 ↗https://www.gesetze-im-internet.de/ebev_2030/anlage_2.html
- Last checked
- 2026-09-26
Other carriers
No default: require the supplier's factor, basis, year and source. Missing factors are a separately warned data gap, never zero.
| Parameter | Value / status |
|---|---|
| LPG | n/a — supplier factor missing |
| District Heating | n/a — supplier factor missing |
| Other | n/a — supplier factor missing |
- Unit / basis
- kg CO₂ per supplier-stated unit
- Effective / applicable period
- Supplier reporting year
- Source
- Supplier-specific declaration required ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Biomass treatment
Biogenic CO₂ is reported separately and not included in the fossil Scope 1 total; upstream, CH₄ and N₂O excluded from this direct-CO₂ screening.
| Parameter | Value / status |
|---|---|
| Value | memo line only |
- Unit / basis
- kg CO₂
- Effective / applicable period
- Reporting year
- Source
- Greenhouse Gas Protocol Scope 1 guidance ↗https://ghgprotocol.org/corporate-standard
- Last checked
- 2026-09-26
Grid electricity factors
Location-based, direct generation CO₂. UBA states 379 g/kWh for 2023. Use the consumption year; if unavailable use the nearest available year and state ‘nearest available factor’ in assumptions.
| Parameter | Value / status |
|---|---|
| 2022 | 0.434 |
| 2023 | 0.379 |
| 2024 | 0.353 |
| 2025 | 0.344 |
- Unit / basis
- kg CO₂/kWh
- Effective / applicable period
- 2022–2025
- Source
- Umweltbundesamt (UBA), German electricity mix ↗https://www.umweltbundesamt.de/themen/co2-emissionen-pro-kilowattstunde-strom-2025-nur
- Last checked
- 2026-09-26
DWD climate factor
Only for an indicative residential energy class when consumption is not already weather-adjusted by the source. Never apply to emissions or electricity.
| Parameter | Value / status |
|---|---|
| Value | optional, user-supplied |
- Unit / basis
- dimensionless heating fuel adjustment
- Effective / applicable period
- Reporting period
- Source
- Deutscher Wetterdienst (DWD), Klimafaktoren ↗https://www.dwd.de/DE/leistungen/klimafaktoren/klimafaktoren.html
- Last checked
- 2026-09-26
Annualisation rules
Most recent consecutive 12 months are complete; 6–11 months with at least 350‰ heating coverage are preliminary. Electricity prorated by calendar days. Show preliminary warning on every derived output.
| Parameter | Value / status |
|---|---|
| Minimum Months | 6 |
| Complete Months | 12 |
| Minimum Heating Coverage Permille | 350 |
- Unit / basis
- consecutive months; ‰ annual heating coverage
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens screening assumption; ista monthly weights ↗https://www.ista.com/de/kontakt-service/fachwissen/gradtagszahlentabelle/
- Last checked
- 2026-09-26
Plausibility bounds
Non-blocking plausibility notice only; the limits are not building performance standards.
| Parameter | Value / status |
|---|---|
| Minimum Final (kWh) Per M2 | 20 |
| Maximum Final (kWh) Per M2 | 500 |
- Unit / basis
- kWh/m²/year entered area basis
- Effective / applicable period
- Methodology version 1.0.0
- Source
- EnergyLens screening assumption ↗https://www.dena.de/
- Last checked
- 2026-09-26
Grid outlook assumption
EnergyLens assumption, not an official projection. Linear between milestones; outlooks must also show the grid factor held constant.
| Parameter | Value / status |
|---|---|
| Start · Year | 2025 |
| Start · Factor | 0.344 |
| Milestones · option 1 · Year | 2030 |
| Milestones · option 1 · Factor | 0.15 |
| Milestones · option 2 · Year | 2045 |
| Milestones · option 2 · Factor | 0.02 |
| After2045 | constant |
| Sensitivity | grid factor held constant |
- Unit / basis
- kg CO₂/kWh
- Effective / applicable period
- 2025–2045
- Source
- EnergyLens assumption based on latest UBA actual value ↗https://www.umweltbundesamt.de/themen/co2-emissionen-pro-kilowattstunde-strom-2025-nur
- Last checked
- 2026-09-26
Market-based electricity memo
Green tariffs or guarantees of origin are excluded from main location-based KPIs; show separately only with documented supplier data.
| Parameter | Value / status |
|---|---|
| Value | memo only when supplier-specific data are supplied |
- Unit / basis
- kg CO₂/kWh
- Effective / applicable period
- Reporting year
- Source
- GHG Protocol Scope 2 Guidance ↗https://ghgprotocol.org/scope-2-guidance
- Last checked
- 2026-09-26
Reduction reference & CO₂ prices
A sector-wide statutory reference is not an individual building target. Price scenarios are assumptions, not forecasts.
German building-sector reference
German building-sector reference (KSG), applied proportionally to this building. A pace-of-reduction reference, not an asset-specific target. The post-2030 linear extension is an EnergyLens assumption, not a statutory asset pathway.
| Parameter | Value / status |
|---|---|
| Annual · 2020 | 118 |
| Annual · 2021 | 113 |
| Annual · 2022 | 108 |
| Annual · 2023 | 102 |
| Annual · 2024 | 97 |
| Annual · 2025 | 92 |
| Annual · 2026 | 87 |
| Annual · 2027 | 82 |
| Annual · 2028 | 77 |
| Annual · 2029 | 72 |
| Annual · 2030 | 67 |
| Assumed End · Year | 2045 |
| Assumed End · Value | 0 |
- Unit / basis
- Mt/year (statutory sector greenhouse-gas reference, not building CO₂)
- Effective / applicable period
- 2020–2030 statutory; 2031–2045 assumption
- Source
- KSG Anlage 2a; KSG §3 for assumed post-2030 end point ↗https://www.gesetze-im-internet.de/ksg/anlage_2a.html
- Last checked
- 2026-09-26
BEHG CO₂ prices
The 2026 and 2027 figures are indicative points within a €55–65/t corridor, not guaranteed prices.
| Parameter | Value / status |
|---|---|
| Annual · 2021 | 25 |
| Annual · 2022 | 30 |
| Annual · 2023 | 30 |
| Annual · 2024 | 45 |
| Annual · 2025 | 55 |
| Annual · 2026 | 60 |
| Annual · 2027 | 60 |
| Corridor · 2026 · option 1 | 55 |
| Corridor · 2026 · option 2 | 65 |
| Corridor · 2027 · option 1 | 55 |
| Corridor · 2027 · option 2 | 65 |
- Unit / basis
- €/t CO₂, nominal, net of VAT
- Effective / applicable period
- 2021–2027
- Source
- BEHG; German Bundestag notice for 2027 ↗https://www.bundestag.de/presse/hib/kurzmeldungen-1210950
- Last checked
- 2026-09-26
ETS2 price scenarios
Scenario assumptions, not forecasts. Linear between points; constant beyond 2035. Low scenario is an indicative nominal proxy for ETS2 price-stability intent, not a verified statutory price.
| Parameter | Value / status |
|---|---|
| Start Year | 2028 |
| Low · option 1 · Year | 2028 |
| Low · option 1 · Value | 60 |
| Low · option 2 · Year | 2035 |
| Low · option 2 · Value | 60 |
| Central · option 1 · Year | 2028 |
| Central · option 1 · Value | 90 |
| Central · option 2 · Year | 2030 |
| Central · option 2 · Value | 110 |
| Central · option 3 · Year | 2035 |
| Central · option 3 · Value | 140 |
| High · option 1 · Year | 2028 |
| High · option 1 · Value | 130 |
| High · option 2 · Year | 2030 |
| High · option 2 · Value | 160 |
| High · option 3 · Year | 2035 |
| High · option 3 · Value | 210 |
| After2035 | constant |
- Unit / basis
- €/t CO₂, nominal, net of VAT
- Effective / applicable period
- 2028–2035
- Source
- EnergyLens scenarios; high case based on EWI Köln 2025 ↗https://www.ewi.uni-koeln.de/cms/wp-content/uploads/2025/04/EU-ETS2_Endbericht.pdf
- Last checked
- 2026-09-26
Residential CO₂ VAT
For residential tenant pass-through, display both net and gross CO₂ costs; verify the applicable invoice and tax treatment.
| Parameter | Value / status |
|---|---|
| Value | 0.19 |
- Unit / basis
- share of net CO₂ costs
- Effective / applicable period
- 2026
- Source
- German VAT Act (UStG), §12 ↗https://www.gesetze-im-internet.de/ustg_1980/__12.html
- Last checked
- 2026-09-26
Cost allocation
Residential allocation uses Wohnfläche and verified billing-period inputs. Exceptions require review.
Residential CO₂ cost allocation
Residential-only tier thresholds; calculate only when verified Wohnfläche, energy carrier and billing-period emissions are supplied.
| Parameter | Value / status |
|---|---|
| · option 1 · Below | 12 |
| · option 1 · Share | 0 |
| · option 2 · Below | 17 |
| · option 2 · Share | 10 |
| · option 3 · Below | 22 |
| · option 3 · Share | 20 |
| · option 4 · Below | 27 |
| · option 4 · Share | 30 |
| · option 5 · Below | 32 |
| · option 5 · Share | 40 |
| · option 6 · Below | 37 |
| · option 6 · Share | 50 |
| · option 7 · Below | 42 |
| · option 7 · Share | 60 |
| · option 8 · Below | 47 |
| · option 8 · Share | 70 |
| · option 9 · Below | 52 |
| · option 9 · Share | 80 |
| · option 10 · From | 52 |
| · option 10 · Share | 95 |
- Unit / basis
- kg CO₂/m² Wohnfläche/year → landlord share %
- Effective / applicable period
- Applicable statute
- Source
- CO2KostAufG ↗https://www.gesetze-im-internet.de/co2kostaufg/
- Last checked
- 2026-09-26
Non-residential CO₂ cost allocation
Predominantly non-residential use; confirm tenancy and statutory exceptions before application.
| Parameter | Value / status |
|---|---|
| Landlord | 50 |
| Tenant | 50 |
- Unit / basis
- % of CO₂ costs
- Effective / applicable period
- Applicable statute
- Source
- CO2KostAufG ↗https://www.gesetze-im-internet.de/co2kostaufg/
- Last checked
- 2026-09-26
New-heating CO₂ cost allocation
Summary of GModG; see the official text.
| Parameter | Value / status |
|---|---|
| Installed After | 2026-07-29 |
| Applies From | 2028-01-01 |
| Landlord | 50 |
| Tenant | 50 |
| Carriers · option 1 | gas |
| Carriers · option 2 | oil |
| Carriers · option 3 | LPG |
- Unit / basis
- % of CO₂ costs
- Effective / applicable period
- 2028-01-01
- Source
- GModG and CO2KostAufG ↗https://www.gmodg.bund.de/GEGPortal/DE/GEGRegelungen/GModG_neu/GModG_neu-node.html
- Last checked
- 2026-09-26
CO₂ cost allocation exceptions
Do not calculate adjustments: flag potential hardship and protected-building exceptions for professional review.
| Parameter | Value / status |
|---|---|
| Hardship | §5d: small landlords with at most 6 units in class G/H |
| Protected Buildings · option 1 | Denkmalschutz |
| Protected Buildings · option 2 | Milieuschutz |
- Unit / basis
- flag only
- Effective / applicable period
- Applicable statute
- Source
- CO2KostAufG; GModG ↗https://www.gesetze-im-internet.de/co2kostaufg/
- Last checked
- 2026-09-26
Energy classes & building rules
Consumption-based residential classes are indicative. Non-residential classes require calculated primary-energy demand and cannot be inferred from bills.
Residential energy classes
Indicative class (consumption-based estimate). Not an Energieausweis. Only authorised issuers can issue an Energieausweis. Boundaries are inclusive except H, which is above 250.
| Parameter | Value / status |
|---|---|
| · option 1 · Class | A+ |
| · option 1 · Max | 30 |
| · option 2 · Class | A |
| · option 2 · Max | 50 |
| · option 3 · Class | B |
| · option 3 · Max | 75 |
| · option 4 · Class | C |
| · option 4 · Max | 100 |
| · option 5 · Class | D |
| · option 5 · Max | 130 |
| · option 6 · Class | E |
| · option 6 · Max | 160 |
| · option 7 · Class | F |
| · option 7 · Max | 200 |
| · option 8 · Class | G |
| · option 8 · Max | 250 |
| · option 9 · Class | H |
| · option 9 · Above | 250 |
- Unit / basis
- kWh/m² AN/year, final energy
- Effective / applicable period
- Applicable statute
- Source
- GEG Anlage 10 ↗https://www.gesetze-im-internet.de/geg/anlage_10.html
- Last checked
- 2026-09-26
Residential area conversion
Use only when AN is unknown and Wohnfläche is documented; 1.35 applies to one- and two-family houses with heated basement. Never substitute NRF or BGF; otherwise class not determined. Convert invoiced gas from Hs to Hi.
| Parameter | Value / status |
|---|---|
| Usual | 1.2 |
| Small House Heated Basement | 1.35 |
- Unit / basis
- m² AN per m² Wohnfläche
- Effective / applicable period
- Applicable statute
- Source
- GEG area approximation guidance ↗https://www.gesetze-im-internet.de/geg/
- Last checked
- 2026-09-26
Non-residential classes
Information only: cannot be derived from bills. Never estimate a class. Verify with an authorised Energieausweis issuer.
| Parameter | Value / status |
|---|---|
| · option 1 · Class | A |
| · option 1 · Max | 1 |
| · option 2 · Class | B |
| · option 2 · Max | 1.48 |
| · option 3 · Class | C |
| · option 3 · Max | 1.97 |
| · option 4 · Class | D |
| · option 4 · Max | 2.46 |
| · option 5 · Class | E |
| · option 5 · Max | 2.95 |
| · option 6 · Class | F |
| · option 6 · Max | 3.5 |
| · option 7 · Class | G |
| · option 7 · Above | 3.5 |
- Unit / basis
- calculated primary-energy demand ÷ reference-building demand
- Effective / applicable period
- 2027-01-01
- Source
- GModG; Gewerbepass summary ↗https://gewerbepass.de/ratgeber-nwg/energieeffizienzklassen
- Last checked
- 2026-09-26
Non-residential improvement dates
Information only; exemptions may apply. Do not infer compliance from bills or from a consumption-based screening.
| Parameter | Value / status |
|---|---|
| · option 1 · From Year | 2030 |
| · option 1 · Above Ratio | 3.5 |
| · option 2 · From Year | 2033 |
| · option 2 · Above Ratio | 2.95 |
- Unit / basis
- primary-energy demand/reference-building ratio
- Effective / applicable period
- 2027-01-01
- Source
- GModG; Gewerbepass summary ↗https://gewerbepass.de/ratgeber-nwg/energieeffizienzklassen
- Last checked
- 2026-09-26
Building-law dates
Supplied legislative dates; verify the promulgated statute before applying to an individual building.
| Parameter | Value / status |
|---|---|
| Published | 2026-07-28 |
| Heating From | 2026-07-29 |
| Epbd From | 2027-01-01 |
- Unit / basis
- calendar dates
- Effective / applicable period
- 2026-07-28
- Source
- GModG; BBSR GEG portal ↗https://www.gmodg.bund.de/GEGPortal/DE/GEGRegelungen/GModG_neu/GModG_neu-node.html
- Last checked
- 2026-09-26
Company reporting & funding
Company-wide reporting obligations and indicative grants cannot be established from an individual building record.
Company reporting scope
Company-level scope only; both thresholds required. ESRS E1-6 GHG intensity is per net revenue, not per m². Check current legislation and company-specific status.
| Parameter | Value / status |
|---|---|
| Employees More Than | 1000 |
| Net Turnover More Than Eur | 450000000 |
| Both Required | true |
- Unit / basis
- employees and €/year net turnover
- Effective / applicable period
- 2026
- Source
- EU Omnibus I, Council adoption summary ↗https://www.regulationtomorrow.com/2026/02/omnibus-i-csrd-and-cs3d-simplification-council-of-european-union-adopts-final-text-t-simplify-sustainability-reporting-and-due-diligence-requirements/
- Last checked
- 2026-09-26
Funding notice
No eligibility, approval or grant is promised; confirm current scheme details directly with the administrators.
| Parameter | Value / status |
|---|---|
| Value | Indicative — verify current conditions at bafa.de / kfw.de before relying on it; eligible-cost caps may reduce the amount |
- Unit / basis
- eligibility notice
- Effective / applicable period
- 2026-07-21
- Source
- BAFA and KfW ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Heat-pump funding
Indicative only; eligibility and caps apply. Owner-occupier bonuses are not modelled. Verify the published funding rules before any calculation.
| Parameter | Value / status |
|---|---|
| Until2027Q1 | 30 |
| From2027Q1Base | 15 |
| Eu Manufactured Bonus | 15 |
- Unit / basis
- % of eligible costs
- Effective / applicable period
- 2026-07-21; Q1 2027 proposed change
- Source
- BEG reform 2026 summary ↗https://www.rebuild-now.com/beg-reform-2026-alle-aenderungen-im-ueberblick/
- Last checked
- 2026-09-26
Building-envelope funding
Indicative; iSFP bonus is residential only and subject to conditions. The non-residential cap may reduce an award.
| Parameter | Value / status |
|---|---|
| Base | 15 |
| Residential Isfp Bonus | 5 |
| Non Residential Cost Cap | 500 |
- Unit / basis
- % of eligible costs; €/m² net floor area cap
- Effective / applicable period
- 2026-07-21
- Source
- BEG EM 2026 non-residential summary ↗https://www.energiekosten360.de/foerderung/beg-2026-nichtwohngebaeude/
- Last checked
- 2026-09-26
Funding exclusions
Indicative only; verify the current funding rules and other potential programmes directly with administrators.
| Parameter | Value / status |
|---|---|
| Non Residential Interior Lighting | not eligible |
| Solar PV | no BEG grant |
| Owner Occupier Bonuses | not modelled |
- Unit / basis
- eligibility flags
- Effective / applicable period
- 2026-07-21
- Source
- BEG reform 2026 summary ↗https://www.rebuild-now.com/beg-reform-2026-alle-aenderungen-im-ueberblick/
- Last checked
- 2026-09-26
Editable modelling inputs
These inputs are assumptions, not measured building performance. Estimates depend on the supplied building evidence.
Boiler seasonal efficiency
User-editable assumptions, not measured efficiencies; unknown gas is not a verified equipment classification.
| Parameter | Value / status |
|---|---|
| Condensing Gas | 0.95 |
| Older Gas | 0.85 |
| Unknown Gas | 0.9 |
| Oil | 0.85 |
- Unit / basis
- fraction, Hi basis
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens engineering assumption ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Heat-pump seasonal performance
User-editable assumptions; results depend on flow temperatures, climate and installation quality.
| Parameter | Value / status |
|---|---|
| Central | 3 |
| Low | 2.5 |
| High | 3.5 |
- Unit / basis
- seasonal coefficient of performance
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens engineering assumption, air-to-water in existing buildings ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Solar PV specific yield
User-editable; use PVGIS for a site-specific value. Do not treat this as a measured yield or grant amount.
| Parameter | Value / status |
|---|---|
| Central | 900 |
| Range · option 1 | 850 |
| Range · option 2 | 1050 |
- Unit / basis
- kWh/kWp/year
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens German typical-yield assumption; PVGIS for site check ↗https://re.jrc.ec.europa.eu/pvg_tools/en/
- Last checked
- 2026-09-26
Heating optimisation
User-editable allowance for hydraulic balancing, heating curve and set-points; no guaranteed savings.
| Parameter | Value / status |
|---|---|
| Central | 5 |
| Range · option 1 | 0 |
| Range · option 2 | 15 |
- Unit / basis
- % of heat demand
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens engineering assumption ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Envelope scenario presets
Scenario, not a calculation. The analyst enters the envelope reduction; presets are not derived from building physics.
| Parameter | Value / status |
|---|---|
| · option 1 | 15 |
| · option 2 | 30 |
| · option 3 | 50 |
- Unit / basis
- % of heat demand
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens analyst presets ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Heat-pump coverage
Share of heat demand supplied by the heat pump; the remainder stays on the existing fossil carrier.
| Parameter | Value / status |
|---|---|
| Central | 100 |
| Range · option 1 | 0 |
| Range · option 2 | 100 |
- Unit / basis
- % of heat demand
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens modelling assumption ↗https://www.bafa.de/
- Last checked
- 2026-09-26
PV feed-in tariff
Default 0 until the analyst enters the applicable tariff. Exported electricity is never deducted from Scope 2.
| Parameter | Value / status |
|---|---|
| Central | 0 |
- Unit / basis
- €/kWh exported, net
- Effective / applicable period
- Model version 1.0.0
- Source
- User input; EEG feed-in tariffs vary by commissioning date and size ↗https://www.bundesnetzagentur.de/
- Last checked
- 2026-09-26
Measure screening rules
Electricity savings above the threshold need sub-metering evidence. Simple payback above the cap is shown only as ‘> 30 years’.
| Parameter | Value / status |
|---|---|
| Electricity Saving Warning Percent | 30 |
| Payback Display Cap Years | 30 |
- Unit / basis
- % of electricity use; years
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens screening rule ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Load-profile rules
Timestamps are interpreted in Europe/Berlin with DST (23- and 25-hour days) unless an ISO offset is given. Indicators are screening estimates, not measured savings.
| Parameter | Value / status |
|---|---|
| Allowed Intervals Minutes · option 1 | 15 |
| Allowed Intervals Minutes · option 2 | 30 |
| Allowed Intervals Minutes · option 3 | 60 |
| Interval Tolerance Minutes | 1 |
| Minimum Days | 28 |
| Recommended Days | 365 |
| Time Zone | Europe/Berlin |
| Zero Run Minimum Intervals | 4 |
| Base Load Percentile | 5 |
| Night Hours · From | 0 |
| Night Hours · To | 5 |
| Default Operating Hours · Weekdays · option 1 | 1 |
| Default Operating Hours · Weekdays · option 2 | 2 |
| Default Operating Hours · Weekdays · option 3 | 3 |
| Default Operating Hours · Weekdays · option 4 | 4 |
| Default Operating Hours · Weekdays · option 5 | 5 |
| Default Operating Hours · From | 7 |
| Default Operating Hours · To | 19 |
| Anomaly Mad Multiplier | 3 |
| Base Load Excess Multiplier | 1.1 |
| Peak Shaving Percentile | 99 |
| Top Peaks | 10 |
| Indicator Label | indicative — requires on-site verification |
- Unit / basis
- minutes; days; percentile; hours local time; multipliers
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens load-profile screening rules ↗https://www.bundesnetzagentur.de/
- Last checked
- 2026-09-26
Report finding rules
Rule-generated findings only; no free AI text in reports.
| Parameter | Value / status |
|---|---|
| Max Findings | 4 |
| Dominant Carrier Share Percent | 50 |
| Outlook Comparison Year | 2030 |
| Cost Years · option 1 | 2026 |
| Cost Years · option 2 | 2030 |
| Exposure Years · From | 2026 |
| Exposure Years · To | 2035 |
| Outlook Years · From | 2024 |
| Outlook Years · To | 2045 |
- Unit / basis
- count; % of CO₂; years
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens report rules ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Not quantified measures
Not quantified — requires site data.
| Parameter | Value / status |
|---|---|
| · option 1 | Domestic hot water system and circulation losses |
| · option 2 | Ventilation heat recovery |
| · option 3 | Building automation and controls |
| · option 4 | Window and door replacement details |
| · option 5 | District-heating connection |
| · option 6 | Heat-distribution upgrades (radiators, flow temperatures) |
- Unit / basis
- list
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens screening scope ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Energieausweis obligation
This screening is not an Energieausweis and cannot replace one.
| Parameter | Value / status |
|---|---|
| Value | On sale, letting or leasing an Energieausweis must be presented; only authorised issuers may prepare it. |
- Unit / basis
- obligation notice
- Effective / applicable period
- 2026-07-29
- Source
- GModG / GEG Energieausweis provisions ↗https://www.gmodg.bund.de/GEGPortal/DE/GEGRegelungen/GModG_neu/GModG_neu-node.html
- Last checked
- 2026-09-26
ESRS building datapoints
E1-6 intensity is per net revenue and must be computed by the reporting company.
| Parameter | Value / status |
|---|---|
| E1_5 | Energy consumption MWh by carrier |
| E1_6 | Scope 1 and Scope 2 (location-based) t CO₂ |
- Unit / basis
- ESRS datapoints
- Effective / applicable period
- 2024-01-01
- Source
- ESRS E1 (Delegated Regulation (EU) 2023/2772) ↗https://eur-lex.europa.eu/eli/reg_del/2023/2772/oj
- Last checked
- 2026-09-26
Company obligations
Company-level obligations are outside this building screening.
| Parameter | Value / status |
|---|---|
| En Ef G_EDLG | Depend on total company energy use — not assessed. |
| Taxonomy Sfdr | Not assessed. |
- Unit / basis
- notice
- Effective / applicable period
- 2023-11-18
- Source
- EnEfG; EDL-G; EU Taxonomy Regulation; SFDR ↗https://www.gesetze-im-internet.de/enefg/
- Last checked
- 2026-09-26
No-cost actions
Qualitative only. No savings percentage is attributed unless operational heating optimisation (step 1) is used.
| Parameter | Value / status |
|---|---|
| · option 1 | Hydraulic balancing |
| · option 2 | Heating curve adjustment |
| · option 3 | Set-back schedules |
| · option 4 | Circulation pump settings |
- Unit / basis
- qualitative checklist
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens screening checklist ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Let residential economics notice
Shown for let residential buildings.
| Parameter | Value / status |
|---|---|
| Value | Energy-cost savings accrue mainly to tenants. Landlord economics depend on the modernisation levy (§559 BGB) and the CO₂ cost share; these are not modelled. |
- Unit / basis
- notice
- Effective / applicable period
- 2026
- Source
- BGB §559; CO2KostAufG ↗https://www.gesetze-im-internet.de/bgb/__559.html
- Last checked
- 2026-09-26
Finance inputs
User-editable, not a quotation or forecast. Model the CO₂ price component separately; zero escalation is an explicit assumption, not missing data.
| Parameter | Value / status |
|---|---|
| Discount Rate | 5 |
| Horizon Years | 20 |
| Energy Price Escalation | 0 |
- Unit / basis
- %/year discount rate; years horizon; %/year price escalation
- Effective / applicable period
- Model version 1.0.0
- Source
- EnergyLens modelling assumption ↗https://www.bafa.de/
- Last checked
- 2026-09-26
Partial-year heating weights
Heating-fuel partial-year annualisation only. Electricity is prorated by actual calendar days. Do not annualise without known coverage dates; estimated figures must be labelled.
| Parameter | Value / status |
|---|---|
| Jan | 170 |
| Feb | 150 |
| Mar | 130 |
| Apr | 80 |
| May | 40 |
| Jun | 13.33 |
| Jul | 13.33 |
| Aug | 13.34 |
| Sep | 30 |
| Oct | 80 |
| Nov | 120 |
| Dec | 160 |
- Unit / basis
- ‰ of annual heating degree-day weight
- Effective / applicable period
- Standard monthly table
- Source
- ista standard Gradtagszahlentabelle ↗https://www.ista.com/de/kontakt-service/fachwissen/gradtagszahlentabelle/
- Last checked
- 2026-09-26