EnergyLens — Regulatory Check — Germany
Rudolf-Wissell-Haus
Alt-Mariendorf 24-26, 12107 Berlin · Germany
- Report type
- Regulatory Check — Germany
- Methodology version
- 1.0.0
- Generated
- —
- Prepared by
- Ali Mert Özdemir, B.Sc. Energy Systems Engineering, M.Sc. Energy Management (in progress)
Public case study based on open data (Datenlizenz Deutschland – Zero – 2.0) published by Bezirksamt Tempelhof-Schöneberg. Independent illustration: the building owner is not an EnergyLens client and has not reviewed this analysis.
1.Inputs
Employees: n/a — not entered · turnover: n/a — not entered · planned replacement: n/a — not entered
2.Checklist
| Topic | Status | Reason | Source |
|---|---|---|---|
| CO2KostAufG (incl. GModG 50/50 rule from 2028) | Not determined | tenancy or heating-cost pass-through unknown. Heaters installed after 2026-07-29: 50/50 split from 2028-01-01. | GModG and CO2KostAufG |
| GModG heating rules and Bio-Treppe (planned heater replacement) | Not determined | No planned heater replacement year entered. | GModG; Görg overview |
| Energieausweis obligation on sale or letting | Not determined | On sale, letting or leasing an Energieausweis must be presented; only authorised issuers may prepare it. Sale or letting plans not entered. | GModG / GEG Energieausweis provisions |
| Non-residential classes A–G (from 2027) and minimum performance 2030/2033 (information) | Does not apply | Residential building. | GModG; Gewerbepass summary |
| CSRD applicability | Not determined | Company employees and net turnover not entered. | EU Omnibus I, Council adoption summary |
| Building data for ESRS (E1-5, E1-6) | Data available | E1-5: Natural gas 585.3 MWh; Electricity 37.1 MWh. E1-6: Scope 1 106.5 t CO₂, Scope 2 location-based 14.1 t CO₂ (2023). E1-6 intensity is per net revenue and must be computed by the reporting company. | ESRS E1 (Delegated Regulation (EU) 2023/2772) |
| EnEfG / EDL-G company obligations | Not determined | Depend on total company energy use — not assessed. | EnEfG; EDL-G; EU Taxonomy Regulation; SFDR |
| EU Taxonomy and SFDR | Not determined | Not assessed. | EnEfG; EDL-G; EU Taxonomy Regulation; SFDR |
3.Data quality and limitations
Rating: Medium — Gas calorific basis assumed; Only NRF published; Wohnfläche and AN unavailable; Energy costs not published; Heating consumption weather-adjusted by source.
Statuses are screening indications from the entered data, not legal advice. Verify the promulgated statutes and individual exemptions with qualified professionals. An Energieausweis may only be issued by authorised issuers.
4.Assumptions and sources
| Item | Value | Type | Source |
|---|---|---|---|
| Area (NRF) | 5,586 m² | public reference | Public record: Bezirksamt Tempelhof-Schöneberg von Berlin — Energieverbrauchsübersicht 2019–2023; Datenlizenz Deutschland – Zero – 2.0 |
| Natural gas consumption 2023 | 585,304 kWh Hs | public reference | Public record: Bezirksamt Tempelhof-Schöneberg von Berlin — Energieverbrauchsübersicht 2019–2023; Datenlizenz Deutschland – Zero – 2.0 |
| Natural gas CO₂ factor | 0.182 kg CO₂/kWh | public reference | EBeV 2030, Anlage 2 |
| Electricity consumption 2023 | 37,117 kWh | public reference | Public record: Bezirksamt Tempelhof-Schöneberg von Berlin — Energieverbrauchsübersicht 2019–2023; Datenlizenz Deutschland – Zero – 2.0 |
| Electricity CO₂ factor | 0.379 kg CO₂/kWh | public reference | Umweltbundesamt (UBA), German electricity mix |
| Gas calorific basis | Hs (invoice) assumed | EnergyLens assumption | EnergyLens assumption (no external source) |
| Grid factor projection | 2025: 0.344 → 2030: 0.150 → 2045: 0.020 kg CO₂/kWh | EnergyLens assumption | EnergyLens assumption (no external source) |
| KSG building-sector reference | 2020: 118 → 2030: 67 Mt/year (statutory sector greenhouse-gas reference, not building CO₂) | public reference | KSG Anlage 2a; KSG §3 for assumed post-2030 end point |
| BEHG CO₂ prices | 2021–2027: 2021 €25 · 2022 €30 · 2023 €30 · 2024 €45 · 2025 €55 · 2026 €60 · 2027 €60 €/t CO₂ net | public reference | BEHG; German Bundestag notice for 2027 |
| ETS2 price scenarios | 2028–2035: low 60–60 · central 90–110–140 · high 130–160–210 €/t CO₂ net | EnergyLens assumption | EnergyLens assumption (no external source) |
| CO2KostAufG residential stages | <12 kg CO₂/m² Wohnfläche/year: 0% · <17 kg CO₂/m² Wohnfläche/year: 10% · <22 kg CO₂/m² Wohnfläche/year: 20% · <27 kg CO₂/m² Wohnfläche/year: 30% · <32 kg CO₂/m² Wohnfläche/year: 40% · <37 kg CO₂/m² Wohnfläche/year: 50% · <42 kg CO₂/m² Wohnfläche/year: 60% · <47 kg CO₂/m² Wohnfläche/year: 70% · <52 kg CO₂/m² Wohnfläche/year: 80% · ≥52 kg CO₂/m² Wohnfläche/year: 95% | public reference | CO2KostAufG |
| Boiler efficiency | Condensing gas 0.95; older gas 0.85; unknown gas 0.9 (Hi basis) | EnergyLens assumption | EnergyLens assumption (no external source) |
| Heat-pump SCOP | Central 3; sensitivity 2.5 and 3.5 (seasonal coefficient of performance) | EnergyLens assumption | EnergyLens assumption (no external source) |
| PV specific yield | 900 kWh/kWp/year (range 850–1050 kWh/kWp/year) | EnergyLens assumption | EnergyLens assumption (no external source) |
| Finance inputs | 5% discount rate; 20 years; 0%/year price escalation | EnergyLens assumption | EnergyLens assumption (no external source) |